Active Filter: Bessel
(2nd order, 12 dB/octave, Lowpass)
R=4.7k-10 kOhm
Ca=0.9076/(2*pi*Fc*R)
Cb=0.6809/(2*pi*Fc*R)
Units: R [Ohm], Cx [F], Fc [Hz]
Contributor:
Joakim Ögren
Source: ?
Please send any comments to
Joakim Ögren
.